• DocumentCode
    817823
  • Title

    A comparison of methods for simulating low dose-rate gamma ray testing of MOS devices

  • Author

    Jenkins, William C. ; Martin, Richard L.

  • Author_Institution
    US Naval Res. Lab., Washington, DC, USA
  • Volume
    38
  • Issue
    6
  • fYear
    1991
  • fDate
    12/1/1991 12:00:00 AM
  • Firstpage
    1560
  • Lastpage
    1566
  • Abstract
    A radiation testing procedure is presented and experimentally verified in which a series of high-dose-rate irradiations, with 100°C annealing under bias between irradiations, is used to simulate a continuous low-dose-rate irradiation. This approach can reduce low-dose-rate testing time by as much as a factor of 100 with respect to actual low-dose-rate irradiations. The procedure also provides detailed information on the behavior of CMOS parts at low dose-rates which are of interest to many satellite systems
  • Keywords
    CMOS integrated circuits; annealing; environmental testing; gamma-ray effects; integrated circuit testing; radiation hardening (electronics); CMOS parts; MOS devices; annealing; high-dose-rate irradiations; low dose-rate gamma ray testing; radiation testing procedure; satellite systems; simulation; Analytical models; Appropriate technology; CMOS technology; Failure analysis; Laboratories; MOS devices; Simulated annealing; Space technology; System testing; Time measurement;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.124146
  • Filename
    124146