• DocumentCode
    818345
  • Title

    A Pulsed Extraction Magnet System at the Zero Gradient Synchrotron (ZGS)

  • Author

    Knott, M. ; Lewis, L. ; Potts, C.

  • Author_Institution
    Argonne National Laboratory Argonne, Illinois
  • Volume
    22
  • Issue
    3
  • fYear
    1975
  • fDate
    6/1/1975 12:00:00 AM
  • Firstpage
    1313
  • Lastpage
    1316
  • Abstract
    Pulsed operation of six extraction magnets has saved $67, 000 in FY 75. Conversion of four six-phase supplies involved some unique analog circuitry. A minicomputer operated function generator provides control of up to 20 magnet power supplies with new dI/dt data available every 4 ms. The operator control console has several options which appreciably decrease set up time and decrease operator error.
  • Keywords
    Costs; Data mining; Microcomputers; Power supplies; Pulse amplifiers; Regulators; Solid state circuits; Synchrotrons; Thermal resistance; Voltage;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1975.4327875
  • Filename
    4327875