• DocumentCode
    819486
  • Title

    Preliminary Design of a Dedicated Synchrotron Radiation Facility

  • Author

    Chasman, R. ; Green, G.K. ; Rowe, E.M.

  • Author_Institution
    Brookhaven National Laboratory Upton, New York 11973
  • Volume
    22
  • Issue
    3
  • fYear
    1975
  • fDate
    6/1/1975 12:00:00 AM
  • Firstpage
    1765
  • Lastpage
    1767
  • Abstract
    An electron storage ring to be used solely as a synchrotron radiation source has been designed for a maximum energy of 1.5 GeV, expandable to 2 GeV, and a maximum current of 1 A, High field superconducting magnet wigglers to serve as hard radiation ports have been incorporated into the ring to make available a wide range of wavelengths for simultaneous experiments. The regular lattice consists of a series of small achromatic bends forming the arcs. The wiggler magnets are placed in low-ß in the center of insertions separating these arcs. The arrangement minimizes the electron emittances and yields high source brightness. Other machine parameters are dictated by experimental requirements and apparatus as well as by cost constraints.
  • Keywords
    Brightness; Electrons; Laboratories; Lattices; Magnetic fields; Spectroscopy; Storage rings; Structural beams; Synchrotron radiation; Undulators;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1975.4327987
  • Filename
    4327987