DocumentCode :
819537
Title :
Tuning of the First Section of the Biomedical Channel at LAMPF
Author :
Paciotti, M.A. ; Bradbury, J.N. ; Helland, J.A. ; Hutson, R.L. ; Knapp, E.A. ; Rivera, O.M. ; Knowles, H.B. ; Pfeufer, G.
Author_Institution :
University of California Los Alamos Scientific Laboratory Los Alamos, NM 87544
Volume :
22
Issue :
3
fYear :
1975
fDate :
6/1/1975 12:00:00 AM
Firstpage :
1784
Lastpage :
1789
Abstract :
Results are presented from the tuning of the first section of the Biomedical Channel at LAMPF; the work centers about the use of the third bending magnet as a magnetic spectrometer. The momentum resolution at the intermediate focus is given in detail. The performance of a wedge degrader that compresses the wide momentum acceptance of the first section is discussed. The output ¿- rate is also given.
Keywords :
Data acquisition; Degradation; Laboratories; Optical scattering; Particle beams; Particle scattering; Production; Solids; Spatial resolution; Spectroscopy;