• DocumentCode
    819855
  • Title

    Permittivity of human skin in millimetre wave band

  • Author

    Alabaster, C.M.

  • Author_Institution
    Dept. of Aerosp., Power & Sensors, Cranfield Univ., Wiltshire, UK
  • Volume
    39
  • Issue
    21
  • fYear
    2003
  • Firstpage
    1521
  • Lastpage
    1522
  • Abstract
    The complex permittivity of a human skin sample is measured over the band 60 to 100 GHz using a quasi-optical method. The results are presented and compared with predictions from standard models. There is a wide range of modelled results; each model providing a partial fit with the measured data.
  • Keywords
    bioelectric phenomena; biological techniques; millimetre wave measurement; permittivity; permittivity measurement; skin; 60 to 100 GHz; biological tissues; complex permittivity; formaldehyde fixing; human skin; millimetre wave band; partial fit; permittivity extrapolation models; quasi-optical method; single ex-vivo sample; standard models;
  • fLanguage
    English
  • Journal_Title
    Electronics Letters
  • Publisher
    iet
  • ISSN
    0013-5194
  • Type

    jour

  • DOI
    10.1049/el:20030967
  • Filename
    1242807