• DocumentCode
    821755
  • Title

    Large Area Reach-Through Avalanche Diodes for X-Ray Spectroscopy

  • Author

    Webb, P.P. ; McIntyre, R.J.

  • Author_Institution
    RCA Limited R&D Laboratories Ste. Anne de Bellevue, Quebec
  • Volume
    23
  • Issue
    1
  • fYear
    1976
  • Firstpage
    138
  • Lastpage
    144
  • Abstract
    Large Area reach-through avalanche diodes have been studied for use in room temperature X-ray spectroscopy applications. Gains in the range 10-80 have been measured, for diodes of area 12 and 25 mms2. Resolutions down to about 600 eV FWHM have been obtained for 5.9 keV X-rays. Various factors limiting resolution are discussed. The useful energy range is approximately 1.5 - 20 keV.
  • Keywords
    Aluminum; Diodes; Electromagnetic wave absorption; Energy resolution; Laboratories; Silicon; Spectroscopy; Temperature; X-ray detection; X-ray detectors;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1976.4328228
  • Filename
    4328228