DocumentCode :
822021
Title :
Delay Line MWPC Hazard Signals Inspector
Author :
Turner, D.B. ; Kirsten, F. ; Guiragossian, Z.G.T. ; Schilling, R.
Author_Institution :
Lawrence Berkeley Laboratory University of California Berkeley, Californiia 94720
Volume :
23
Issue :
1
fYear :
1976
Firstpage :
286
Lastpage :
288
Abstract :
The Hazard Inspector is a CAMAC module which divides a MWPC delay line into 8 independent signal monitor and control segments. Independent control effectively reduces delay line occupation time and cuts the number of background and non-trigger particles accepted by the 4XQT charge-time-pulse-width digitizer, a device presented in a separate communication. Only segments containing legitimate information are digitized. Non-trigger related events are gated out at the digitizer, and contaminating hits are noted for computer correction.
Keywords :
CAMAC; Communication system control; Computerized monitoring; Delay effects; Delay lines; Energy resolution; Hazards; Laboratories; Research and development; Signal analysis;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1976.4328255
Filename :
4328255
Link To Document :
بازگشت