DocumentCode :
822401
Title :
The HEAO-B Imaging Proportional Counter Design
Author :
Harvey, P. ; Sanders, J. ; Cabral, R. ; Morris, J. ; Bjorkholm, P. ; Ballas, J. ; Jagoda, N. ; Harnden, R.B.
Author_Institution :
American Science and Engineering, Inc. Cambridge, Massachusetts 02139
Volume :
23
Issue :
1
fYear :
1976
Firstpage :
487
Lastpage :
492
Abstract :
The HEAO-B Imaging Proportional Counter is an X-ray imaging instrument designed for use in an orbiting observatory. It measures the spatial location and energy of individual X-ray photons by the risetime method and pulse height analysis respectively. The IPC can locate 0.1 to 4keV photons to within 1mm, and provides five bits of energy information. The IPC also includes an in-flight calibration source and a gas control system that maintains the counter gas density constant to an accuracy of 0.25%.
Keywords :
Calibration; Control systems; Counting circuits; Energy measurement; Extraterrestrial measurements; Instruments; Observatories; Optical imaging; Pulse measurements; X-ray imaging;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1976.4328293
Filename :
4328293
Link To Document :