A Microprocessor Based Environmental Radiation Monitoring System
Author :
McCormick, Dan J. ; Glesius, Fred L. ; Kroon, John C.
Author_Institution :
Reuter-Stokes, Inc. Cleveland, Ohio
Volume :
23
Issue :
1
fYear :
1976
Firstpage :
710
Lastpage :
714
Abstract :
A multisensor environmental radiation monitoring system utilizing pressurized ionization chambers is described. The system is capable of measuring incremental increases in gamma radiation exposure of the order of 1 mrad/year due to gaseous effluents from nuclear power plants. Continuous monitoring at a number of sites at or beyond the reactor boundary is performed automatically under control of a microprocessor-based central data acquisition facility. The exposure rate record from each sensor is reduced to a convenient form which can be used to easily determine the reactor plume contribution to the total exposure.
Keywords :
Computerized monitoring; Effluents; Gamma rays; Inductors; Ionization chambers; Microprocessors; Nuclear measurements; Power generation; Power measurement; Radiation monitoring;