• DocumentCode
    823410
  • Title

    Laser-Initiated Vacuum ARC for Heavy Ion Sources

  • Author

    Hirshfield, J.L.

  • Author_Institution
    Mason Laboratory, Yale University New Haven, Connecticut 06520
  • Volume
    23
  • Issue
    2
  • fYear
    1976
  • fDate
    4/1/1976 12:00:00 AM
  • Firstpage
    1006
  • Lastpage
    1007
  • Abstract
    Laser-triggered discharges have been considered for some time both for electron[1] and ion[2] sources. It has been recently shown that conventionally triggered metal-vapor vacuum arcs[3] can sustain even higher ion currents. In this paper, we point out that laser initiation permits arc operation in a high-current regime, and with geometry attractive for heavy ion sources. We present preliminary data on laser-initiated vacuum arcs [4] using carbon, copper, and tungsten cathode electrodes. Discharge current pulses of over 104 amperes with durations of up to 1 msec were employed to yield fully ionized source plasmas of liters volume with ion densities greater than 1013 cm-3. Electrode erosion rates were in the range of 10-4gm/C (the same order as in vacuum arcs) corresponding to ion injection currents in the range of 103 amperes.
  • Keywords
    Cathodes; Copper; Electrodes; Fault location; Geometrical optics; Ion sources; Plasma density; Plasma sources; Tungsten; Vacuum arcs;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1976.4328392
  • Filename
    4328392