DocumentCode :
823675
Title :
Rapid gridding reconstruction with a minimal oversampling ratio
Author :
Beatty, Philip J. ; Nishimura, Dwight G. ; Pauly, John M.
Author_Institution :
Magnetic Resonance Syst. Res. Lab., Stanford Univ., CA, USA
Volume :
24
Issue :
6
fYear :
2005
fDate :
6/1/2005 12:00:00 AM
Firstpage :
799
Lastpage :
808
Abstract :
Reconstruction of magnetic resonance images from data not falling on a Cartesian grid is a Fourier inversion problem typically solved using convolution interpolation, also known as gridding. Gridding is simple and robust and has parameters, the grid oversampling ratio and the kernel width, that can be used to trade accuracy for computational memory and time reductions. We have found that significant reductions in computation memory and time can be obtained while maintaining high accuracy by using a minimal oversampling ratio, from 1.125 to 1.375, instead of the typically employed grid oversampling ratio of two. When using a minimal oversampling ratio, appropriate design of the convolution kernel is important for maintaining high accuracy. We derive a simple equation for choosing the optimal Kaiser-Bessel convolution kernel for a given oversampling ratio and kernel width. As well, we evaluate the effect of presampling the kernel, a common technique used to reduce the computation time, and find that using linear interpolation between samples adds negligible error with far less samples than is necessary with nearest-neighbor interpolation. We also develop a new method for choosing the optimal presampled kernel. Using a minimal oversampling ratio and presampled kernel, we are able to perform a three-dimensional (3-D) reconstruction in one-eighth the time and requiring one-third the computer memory versus using an oversampling ratio of two and a Kaiser-Bessel convolution kernel, while maintaining the same level of accuracy.
Keywords :
Fourier analysis; biomedical MRI; convolution; grid computing; image reconstruction; interpolation; medical image processing; Cartesian grid; Fourier inversion problem; Kaiser-Bessel convolution kernel; linear interpolation; magnetic resonance images; minimal oversampling ratio; nearest-neighbor interpolation; rapid gridding reconstruction; three-dimensional image reconstruction; Convolution; Fourier transforms; Grid computing; Image reconstruction; Interpolation; Kernel; Magnetic resonance; Magnetic resonance imaging; Robustness; Sampling methods; Convolution interpolation; gridding; kernel function; three-dimensional (3-D) reconstruction; Algorithms; Humans; Image Enhancement; Image Interpretation, Computer-Assisted; Imaging, Three-Dimensional; Information Storage and Retrieval; Magnetic Resonance Imaging; Numerical Analysis, Computer-Assisted; Reproducibility of Results; Sample Size; Sensitivity and Specificity; Signal Processing, Computer-Assisted;
fLanguage :
English
Journal_Title :
Medical Imaging, IEEE Transactions on
Publisher :
ieee
ISSN :
0278-0062
Type :
jour
DOI :
10.1109/TMI.2005.848376
Filename :
1435541
Link To Document :
بازگشت