Abstract :
A megachannel pulse-height analysis system using a PDP-8/E computer and two moving-head disk memories has been developed. The system has a storage capacity of 220 memory locations, is capable of processing 1100 events/s, and provides on-line sorting and disk storage. An X- or Y-pulse-height spectrum in coincidence with one or several arbitrary pulse-height windows can be assembled in core for scope display and spectral analysis within 2 to 20 seconds. Reconstruction of a complete X- or Y-pulse-height spectrum requires about 3 minutes.
Keywords :
Assembly; Buffer storage; Computer displays; Costs; Data acquisition; Energy resolution; Gamma ray detection; Gamma ray detectors; Sorting; Spectral analysis;