DocumentCode :
827008
Title :
A Fast-Neutron Detector for Use as a Criticality Monitor
Author :
Friesen, Richard D.
Author_Institution :
Lawrence Livermore Laboratory, University of California, Livermore, California 94550
Volume :
24
Issue :
1
fYear :
1977
Firstpage :
657
Lastpage :
658
Abstract :
To increase the reliability of the criticality monitoring system in a diagnostic chemistry area and to reduce the number of false alarms, a new monitoring system was built using a fast-neutron detector. This paper outlines the design requirements, describes the system as it was built, and reports on the results of several months of operation. The new monitor has proven much more useful than the gamma-detector system it replaced.
Keywords :
Accidents; Buildings; Chemistry; Detectors; Laboratories; Monitoring; Neutrons; Photodiodes; Photomultipliers; System testing;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1977.4328760
Filename :
4328760
Link To Document :
بازگشت