Title :
A Fast-Neutron Detector for Use as a Criticality Monitor
Author :
Friesen, Richard D.
Author_Institution :
Lawrence Livermore Laboratory, University of California, Livermore, California 94550
Abstract :
To increase the reliability of the criticality monitoring system in a diagnostic chemistry area and to reduce the number of false alarms, a new monitoring system was built using a fast-neutron detector. This paper outlines the design requirements, describes the system as it was built, and reports on the results of several months of operation. The new monitor has proven much more useful than the gamma-detector system it replaced.
Keywords :
Accidents; Buildings; Chemistry; Detectors; Laboratories; Monitoring; Neutrons; Photodiodes; Photomultipliers; System testing;
Journal_Title :
Nuclear Science, IEEE Transactions on
DOI :
10.1109/TNS.1977.4328760