• DocumentCode
    827101
  • Title

    Characterization of Platinum Self-Powered Detectors

  • Author

    Lynch, G.F. ; Shields, R.B. ; Coulter, P.G.

  • Author_Institution
    Atomic Energy of Canada Limited Chalk River Nuclear Laboratories Chalk River, Ontario, Canada
  • Volume
    24
  • Issue
    1
  • fYear
    1977
  • Firstpage
    692
  • Lastpage
    695
  • Abstract
    Because platinum self-powered flux detectors have a mixed (neutron and gamma-ray) response in reactor radiation fields, an experimental program was undertaken to characterize these devices. This paper describes experiments performed to determine the response parameters for Pt detectors in a heavy-water moderated reactor. Absolute y-ray and neutron sensitivities were derived from these measurements for detectors with three different emitter diameters, and the results are comrpared with previously reported values.
  • Keywords
    Delay; Event detection; Gamma ray detection; Gamma ray detectors; Gas detectors; Inductors; Neutrons; Platinum; Signal detection; Signal processing;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1977.4328769
  • Filename
    4328769