DocumentCode
827165
Title
Qualification of Class Ie Transmitters
Author
Garber, Irwin ; Miller, Richard B.
Author_Institution
Westinghouse Electric Corporation Pittsburgh, Pennsylvania
Volume
24
Issue
1
fYear
1977
Firstpage
736
Lastpage
741
Abstract
This paper covers the Demonstration Test Program for safety-related transmitters/ resistance temperature detectors as a result of changing system and regulatory requirements. The program includes the test plan, results related to heat transfer characteristics of transmitter, base-line-design, and problems associated with the implementation of the test program. In the latter sections of the paper, a grogram is identified to meet IEEE-323-1974. This program, which covers the environmental qualification of Westinghouse safety related equipment, deals with a realistic approach to aging of equipment located inside of the containment. Aging of equipment located outside of the containment is not done. Although this paper, at times, uses the term equipment in some of the discussions as related to the program presented, it should be understood that transmitters/resistance temperature detectors are included.
Keywords
Aging; Detectors; Electric resistance; Electrical equipment industry; Qualifications; Standards development; System testing; Systems engineering and theory; Temperature; Transmitters;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.1977.4328776
Filename
4328776
Link To Document