• DocumentCode
    827165
  • Title

    Qualification of Class Ie Transmitters

  • Author

    Garber, Irwin ; Miller, Richard B.

  • Author_Institution
    Westinghouse Electric Corporation Pittsburgh, Pennsylvania
  • Volume
    24
  • Issue
    1
  • fYear
    1977
  • Firstpage
    736
  • Lastpage
    741
  • Abstract
    This paper covers the Demonstration Test Program for safety-related transmitters/ resistance temperature detectors as a result of changing system and regulatory requirements. The program includes the test plan, results related to heat transfer characteristics of transmitter, base-line-design, and problems associated with the implementation of the test program. In the latter sections of the paper, a grogram is identified to meet IEEE-323-1974. This program, which covers the environmental qualification of Westinghouse safety related equipment, deals with a realistic approach to aging of equipment located inside of the containment. Aging of equipment located outside of the containment is not done. Although this paper, at times, uses the term equipment in some of the discussions as related to the program presented, it should be understood that transmitters/resistance temperature detectors are included.
  • Keywords
    Aging; Detectors; Electric resistance; Electrical equipment industry; Qualifications; Standards development; System testing; Systems engineering and theory; Temperature; Transmitters;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1977.4328776
  • Filename
    4328776