DocumentCode
82794
Title
Efficient integral cylindrical transmission-line matrix modelling of a coaxially loaded probe-coupled cavity
Author
Jokovic, Jugoslav ; Dimitrijevic, Tijana ; Doncov, Nebojsa ; Milovanovic, Bratislav
Author_Institution
Fac. of Electron. Eng., Univ. of Nis, Niš, Serbia
Volume
9
Issue
8
fYear
2015
fDate
6 5 2015
Firstpage
788
Lastpage
794
Abstract
The transmission-line matrix method enhanced with the compact wire model in a cylindrical grid is used for modelling of a coaxially loaded cylindrical cavity resonator with probes inserted into the cavity. Benefits of using a cylindrical grid instead of rectangular, related to precise modelling of cavity boundaries, a coaxially shaped dielectric sample and radially placed wire elements, are explored. The accuracy of the simulated results is verified by measurements of an experimental model of the cavity-wire structure.
Keywords
cavity resonators; transmission line matrix methods; cavity boundaries; cavity-wire structure; compact wire model; cylindrical cavity resonator; cylindrical grid; integral cylindrical transmission-line matrix modelling; probe-coupled cavity; transmission-line matrix method; wire elements;
fLanguage
English
Journal_Title
Microwaves, Antennas & Propagation, IET
Publisher
iet
ISSN
1751-8725
Type
jour
DOI
10.1049/iet-map.2014.0587
Filename
7115225