• DocumentCode
    828683
  • Title

    New Method Based on Immunity Tests for Shield Maintenance of Wired Electronic Systems

  • Author

    Perea, Eugenio ; Zabala, Eduardo ; Rodriguez-Seco, J.E.

  • Author_Institution
    LABEIN, TECNALIA, Derio
  • Volume
    50
  • Issue
    3
  • fYear
    2008
  • Firstpage
    603
  • Lastpage
    611
  • Abstract
    Shielding maintenance of a complex cable harnesses which transmit measurement, control, or other type of signals to electronic shielded devices is a difficult and unsolved task in the electromagnetic compatibility community. Several methods have been developed for this purpose during the past years. The vast majority of these methods needs to dismantle and then reconnect the wired electronic system for maintenance test purposes. This paper presents and analyzes a new method based on immunity tests for shielding maintenance of wired electronic systems. The proposed method avoids the cable system disconnection and attacks the problem from the immunity point of view.
  • Keywords
    cable shielding; electromagnetic compatibility; electromagnetic shielding; cable system attack; cable system disconnection; complex cable harnesses; electromagnetic compatibility; immunity tests; shield maintenance; shielding maintenance; wired electronic systems; Cable shielding; Connectors; Electromagnetic compatibility; Electromagnetic measurements; Electromagnetic shielding; Electronic equipment testing; Immunity testing; Impedance; Reflectometry; System testing; Electromagnetic compatibility; electromagnetic coupling; electromagnetic shielding; maintenance; wired electronic systems;
  • fLanguage
    English
  • Journal_Title
    Electromagnetic Compatibility, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9375
  • Type

    jour

  • DOI
    10.1109/TEMC.2008.926899
  • Filename
    4591401