Title :
The relationship between size and power dissipation in a 1-10 MHz transformer
Author :
Goldberg, Andrew F. ; Schlecht, Martin F.
Author_Institution :
J.P. Morgan Investment, New York, NY, USA
fDate :
1/1/1992 12:00:00 AM
Abstract :
The trade-off between size and power dissipation in the design of low-profile 1-10 MHz transformers with planar spiral windings is considered. For a fixed power loss and number of conductor layers, the transformer with the smallest possible footprint can be designed by a trade-off of core and copper loss. The relationship between the marginal reduction of the transformer footprint and the associated marginal increase in power dissipation and/or number of conductor layers for the design of the smallest possible transformer is discussed
Keywords :
losses; transformer cores; transformer windings; transformers; 1 to 10 MHz; conductor layers; copper loss; core loss; planar spiral windings; power dissipation; size; transformer; transformer footprint; Conductors; Copper; Helium; Integrated circuit interconnections; Power dissipation; Printed circuits; Skin; Spirals; Transformer cores; Wounds;
Journal_Title :
Power Electronics, IEEE Transactions on