DocumentCode :
828986
Title :
Longitudinal Phenomena in the CERN SPS
Author :
Boussard, D. ; Dome, G. ; Linnecar, T. ; Millich, A.
Author_Institution :
CERN Geneva, Switzerland
Volume :
24
Issue :
3
fYear :
1977
fDate :
6/1/1977 12:00:00 AM
Firstpage :
1399
Lastpage :
1401
Abstract :
After almost one year of operation two kinds of problems dominate the longitudinal behaviour of the SPS beam. At high energy longitudinal coupled bunch instabilities occur. They are driven by the RF cavity impedance both on its fundamental and high-order passbands. Present cures include damping the high-order modes of the cavities, Landau damping techniques and feedback systems. At the injection energy a debunching-rebunching procedure is performed in order to change from the 9.5 MHz RF frequency of the injector to the 200 MHz of the SPS. Debunched beam instabilities driven by the cavity and vacuum chamber impedances (up to the GHz region) at present limit the RF capture efficiency.
Keywords :
Acceleration; Couplers; Damping; Impedance; Power amplifiers; Power system reliability; Pulse amplifiers; Radio frequency; Radiofrequency amplifiers; Voltage;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1977.4328957
Filename :
4328957
Link To Document :
بازگشت