DocumentCode :
830632
Title :
Three phase AC-DC load and harmonic flows
Author :
Arrillaga, J. ; Callaghan, C.D.
Author_Institution :
Canterbury Univ., New Zealand
Volume :
6
Issue :
1
fYear :
1991
fDate :
1/1/1991 12:00:00 AM
Firstpage :
238
Lastpage :
244
Abstract :
The validity of assuming that the fundamental frequency load flow conditions of an AC-DC conversion plant are unaffected by the presence of harmonics is questioned, and an algorithm is derived which is capable of determining the true load flow conditions in the presence of harmonics. The algorithm is unique in its three phase approach to the problem, which is essential if normally unfiltered uncharacteristic harmonics are to be represented. Results of a realistic and relevant test system are used to demonstrate the interaction which exists between the fundamental and harmonic frequencies in the power converter
Keywords :
harmonics; load flow; power convertors; power systems; AC/DC power convertors; algorithm; fundamental frequency; harmonics; load flow; power systems; three phase; Admittance; Converters; Equations; Frequency domain analysis; Impedance; Mutual coupling; Power generation; Power transmission lines; Printing; Voltage;
fLanguage :
English
Journal_Title :
Power Delivery, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-8977
Type :
jour
DOI :
10.1109/61.103743
Filename :
103743
Link To Document :
بازگشت