DocumentCode :
831961
Title :
Surge Protection for Pipeline Motors
Author :
Shankle, Derrill F. ; Edwards, Robert F. ; Moses, Graham L.
Author_Institution :
Westinghouse Electric Corporation
Issue :
2
fYear :
1968
fDate :
3/1/1968 12:00:00 AM
Firstpage :
171
Lastpage :
176
Abstract :
Recent field tests on motors in service on pipelines and powerhouse systems have shown that the switching surge voltage appearing at the motor terminals during initial energization for starting frequently reach magnitudes approaching 2.0 per unit normal crest line-to-ground operating voltage with time-to-crest as short as 0.2 As. This is more severe than normally believed and may endanger turn-to-turn insulation.
Keywords :
AC motors; Capacitance; Capacitors; Coils; Dielectrics and electrical insulation; Pipelines; Stress; Surge protection; Surges; Voltage;
fLanguage :
English
Journal_Title :
Industry and General Applications, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-943X
Type :
jour
DOI :
10.1109/TIGA.1968.4180873
Filename :
4180873
Link To Document :
بازگشت