DocumentCode :
832008
Title :
Tracking the optic nervehead in OCT video using dual eigenspaces and an adaptive vascular distribution model
Author :
Koozekanani, Dara ; Boyer, Kim L. ; Roberts, Cynthia
Author_Institution :
Biomed. Eng. Program, Ohio State Univ., Columbus, OH, USA
Volume :
22
Issue :
12
fYear :
2003
Firstpage :
1519
Lastpage :
1536
Abstract :
Optical coherence tomography (OCT) is a new ophthalmic imaging modality generating cross sectional views of the retina. OCT systems are essentially Michelson interferometers that form images in 1.5 s by directing a superluminescent diode (SLD) beam over the retinal surface. Involuntary eye motions frequently cause incorrect locations to be imaged. This motion may leave no obvious artifacts in the scan data and can easily go undetected. For glaucoma monitoring especially, knowing the measurement path, typically a circle concentric with the nerve head, is crucial. The commercially available OCT system displays a near-infrared video of the retina showing the SLD beam. This paper presents a prototype system to detect the nerve head and SLD beam in the video, and report the true scan path relative to the nerve head. Low image contrast and limited resolution make the reliable detection of retinal features difficult. In an adaptive model construction phase, the system directly detects retinal vasculature and the nerve head and incrementally builds a model of the current subject´s vascular pattern relative to the optic disk. The nerve head identification is multitiered, using a novel dual eigenspace technique and a geometric comparison of detected vessel positions and nerve head hypotheses. In its operational phase, a correspondence is achieved between the currently detected vasculature and the model. Using subjects not included in training, the system located the optic nerve head to within 5 pixels (0.07 optic disk diameters, an error well below clinical significance) in 99.75% of 2800 video fields. In current clinical practice, motions as large as 1-2 disc diameters may go undetected, so this is a vast improvement.
Keywords :
biomedical optical imaging; blood vessels; eigenvalues and eigenfunctions; eye; medical image processing; neurophysiology; optical tomography; physiological models; video signal processing; Michelson interferometers; adaptive model construction phase; cross sectional views; dual eigenspace technique; fundus imaging; geometric comparison; glaucoma monitoring; nerve head; ophthalmology; optic disk; optical coherence tomography; prototype system; retinal surface; retinal vasculature; superluminescent diode beam; vascular pattern; vessel positions; video tracking; Adaptive optics; Coherence; Geometrical optics; Head; Optical interferometry; Phase detection; Retina; Structural beams; Superluminescent diodes; Tomography; Algorithms; Expert Systems; Feedback; Humans; Image Enhancement; Image Interpretation, Computer-Assisted; Movement; Ophthalmoscopy; Optic Disk; Pattern Recognition, Automated; Retinal Vessels; Tomography, Optical Coherence; Video Recording;
fLanguage :
English
Journal_Title :
Medical Imaging, IEEE Transactions on
Publisher :
ieee
ISSN :
0278-0062
Type :
jour
DOI :
10.1109/TMI.2003.817753
Filename :
1247782
Link To Document :
بازگشت