• DocumentCode
    832853
  • Title

    Recent Improvements in HgI2 Detectors

  • Author

    van den Berg, L. ; Whited, R.C.

  • Author_Institution
    EG&G, Santa Barbara Operations, Goleta, CA
  • Volume
    25
  • Issue
    1
  • fYear
    1978
  • Firstpage
    395
  • Lastpage
    397
  • Abstract
    Development of mercuric iodide nuclear detectors in our laboratory has concentrated on crystalline perfection, optimization of electronic properties, and device fabrication. Increased crystalline perfection can be obtained with better crystal growth temperature control combined with slightly modified growth parameters. Adjustment of the stoichiometry of the crystal growth source material has increased the mobility-trapping time (¿¿) product for the holes. Preliminary experiments with different contact materials and contacting techniques gave ambivalent results.
  • Keywords
    Collimators; Cooling; Crystalline materials; Crystallization; Detectors; Electron traps; Laboratories; Mercury (metals); Nuclear electronics; Temperature control;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1978.4329338
  • Filename
    4329338