DocumentCode
832974
Title
Gas Control System for HEAO-B
Author
Taylor, B. ; Brissette, R. ; Humphrey, A. ; Morris, J. ; Luger, J. ; Swift, W.
Author_Institution
American Science and Engineering, Inc. Cambridge, Massachusetts 02139
Volume
25
Issue
1
fYear
1978
Firstpage
467
Lastpage
472
Abstract
The HEAO-Bb Gas Control System consists of a high pressure gas storage supply together with distribution and regulation assemblies and their associated electronics for management of gas required for HEAO-B X-ray counter experiments. The Gas Control System replenishes a gas mixture (82 percent Argon, 12.3 percent Carbon Dioxide, 5.7 percent Xenon) in the counter volumes which is lost by: diffusion through controlled leakage plugs, diffusion through counter windows, and consumption resulting from periodic purges. The gas density in each counter volume is maintained constant to within 0.25 percent by comparison with a sealed reference volume. The system is fully redundant, capable of operating at atmospheric pressure as well as in a vacuum, contains interlocks which shut down gas flow in the event of either leakage or excessive pressure, and is able to shut down counter high voltage if counter pressure is abnormally low. The system is electronically controlled by ground command and self-sustaining in orbit for a period of at least one year.
Keywords
Argon; Assembly systems; Carbon dioxide; Control systems; Counting circuits; Fluid flow; Plugs; Pressure control; Vacuum systems; Xenon;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.1978.4329350
Filename
4329350