• DocumentCode
    833220
  • Title

    Initial performance of the SLD Cherenkov ring imaging detector system

  • Author

    Abe, K. ; Antilogus, P. ; Aston, D. ; Baird, K. ; Bean, A. ; Bienz, T. ; Bird, F. ; Caldwell, D. ; Cavalli-Sforza, M. ; Coyle, P. ; Coyne, D. ; Dasu, S. ; Dolinsky, S. ; d´Oliveira, A. ; Duboscq, J. ; Dunwoodie, W. ; Gagnon, P. ; Hallewell, G. ; Hasegawa,

  • Author_Institution
    SLAC, Stanford Univ., CA, USA
  • Volume
    39
  • Issue
    4
  • fYear
    1992
  • Firstpage
    685
  • Lastpage
    689
  • Abstract
    The SLD barrel Cherenkov ring imaging detector (CRID) system was designed to allow excellent particle identification in the study of Z/sup 0/ physics at the Stanford Linear Accelerator Center linear collider. The CRID system participated in the SLD engineering run of June-August 1991. In a cosmic ray test at the end of the run, Cherenkov rings were observed for the first time. Initial data from the CRID, including Cherenkov rings, studies of minimum ionizing particles, and data from the fiber-optics calibration system are presented.<>
  • Keywords
    Cherenkov counters; calibration; position sensitive particle detectors; CRID system; SLAC; SLD barrel Cherenkov ring imaging detector; SLD engineering run; fiber-optics calibration system; minimum ionizing particles; particle identification; Calibration; Detectors; Laboratories; Optical fiber testing; Optical fibers; Optical imaging; Physics; Superluminescent diodes; System testing; USA Councils;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/23.159688
  • Filename