DocumentCode :
833245
Title :
Starting Requirements and Effects of Large Synchronous Motors
Author :
Zimmerman, J.A. ; Hauck, T.A.
Author_Institution :
Allis-Chalmers Manufacturing Company
Issue :
2
fYear :
1969
fDate :
3/1/1969 12:00:00 AM
Firstpage :
169
Lastpage :
175
Abstract :
Modem cement plants require an ever increasing sensitivity toward the application of large synchronous motors. Choosing the correct drive, based on load requirements, necessitates a thorough investigation of power availability and its effect on starting, acceleration, and pull-in characteristics of the motor. Also of concern is how these characteristics can be altered by design; or by the installation of auxiliary equipment, which may improve conditions not totally possible by design alone.
Keywords :
Acceleration; Cement industry; Circuits; Frequency; Milling machines; Resistors; Rotors; Stators; Synchronous motors; Torque;
fLanguage :
English
Journal_Title :
Industry and General Applications, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-943X
Type :
jour
DOI :
10.1109/TIGA.1969.4181008
Filename :
4181008
Link To Document :