Abstract
The CERN neutrino beam is monitored via the accompanying muon flux in the iron shield. Silicon radiation detectors are used for measuring this flux at several places in the shield. Special features of the electronics are the low noise cable connection to the remote preamplifier and the leakage current compensatior. The precise calibration of the detectors allows detailed information on the neutrino flux.
Keywords
Cable shielding; Calibration; Iron; Leakage current; Mesons; Neutrino sources; Preamplifiers; Remote monitoring; Silicon radiation detectors; Solid state circuits;