Title :
Investigations of Nonlinearities and Multiple Exposure Anomalies of Shielded Cables at CASINO
Author :
Chivington, E.P. ; Clement, D.M. ; Wuller, C.E. ; Madle, P.J.
Author_Institution :
TRW Defense and Space Systems Group Redondo Beach, California 90278
fDate :
6/1/1978 12:00:00 AM
Abstract :
Photon tests of several types of cables, performed at the CASINO facility, provide benchmark data on high dose effects in cable response to direct-injection currents. Shielded hookup wire response was found to be linear with dose up to 50 krad (CaF2) in vacuum. The cable response in air was opposite in polarity from response in vacuum and of comparable magnitude. A slight, anomalous, first-shot response was observed in a semirigid coaxial cable sample where the direct injection is normally small. Calculations performed with the MCCABE code compare well with measured response.
Keywords :
Cable shielding; Coaxial cables; Dielectrics; History; Ionization; Oscilloscopes; Performance evaluation; Pressure control; System testing; Wire;
Journal_Title :
Nuclear Science, IEEE Transactions on
DOI :
10.1109/TNS.1978.4329456