DocumentCode
83496
Title
Quantifying the Statistical Impact of GRAPPA in fcMRI Data With a Real-Valued Isomorphism
Author
Bruce, Iain P. ; Rowe, Daniel B.
Author_Institution
Dept. of Math., Stat. & Comput. Sci., Marquette Univ., Milwaukee, WI, USA
Volume
33
Issue
2
fYear
2014
fDate
Feb. 2014
Firstpage
495
Lastpage
503
Abstract
The interpolation of missing spatial frequencies through the generalized auto-calibrating partially parallel acquisitions (GRAPPA) parallel magnetic resonance imaging (MRI) model implies a correlation is induced between the acquired and reconstructed frequency measurements. As the parallel image reconstruction algorithms in many medical MRI scanners are based on the GRAPPA model, this study aims to quantify the statistical implications that the GRAPPA model has in functional connectivity studies. The linear mathematical framework derived in the work of Rowe , 2007, is adapted to represent the complex-valued GRAPPA image reconstruction operation in terms of a real-valued isomorphism, and a statistical analysis is performed on the effects that the GRAPPA operation has on reconstructed voxel means and correlations. The interpolation of missing spatial frequencies with the GRAPPA model is shown to result in an artificial correlation induced between voxels in the reconstructed images, and these artificial correlations are shown to reside in the low temporal frequency spectrum commonly associated with functional connectivity. Through a real-valued isomorphism, such as the one outlined in this manuscript, the exact artificial correlations induced by the GRAPPA model are not simply estimated, as they would be with simulations, but are precisely quantified. If these correlations are unaccounted for, they can incur an increase in false positives in functional connectivity studies.
Keywords
biomedical MRI; calibration; frequency measurement; image reconstruction; interpolation; isomorphism; medical image processing; statistical analysis; acquired frequency measurements; artificial correlation; complex-valued GRAPPA image reconstruction operation; fcMRI data; functional connectivity studies; generalized autocalibrating partially parallel acquisitions parallel magnetic resonance imaging; linear mathematical framework; low temporal frequency spectrum; medical MRI scanners; missing spatial frequencies interpolation; parallel image reconstruction algorithms; real-valued isomorphism; reconstructed frequency measurements; reconstructed voxel means; statistical analysis; statistical impact quantification; Coils; Correlation; Image reconstruction; Interpolation; Kernel; Time series analysis; Vectors; Connectivity analysis; functional magnetic resonance imaging (fMRI); image reconstruction; magnetic resonance imaging (MRI); parallel imaging; quantification and estimation;
fLanguage
English
Journal_Title
Medical Imaging, IEEE Transactions on
Publisher
ieee
ISSN
0278-0062
Type
jour
DOI
10.1109/TMI.2013.2288521
Filename
6656901