  • Title

    Probabilistic Evaluation of Failure Modes Leading to the Mispositioning of Certain ECCS Motor Operated Valves in WestingHouse NSSS

  • Author

    Barlow, R.T. ; Hill, R.A. ; McIntire, D.C. ; O´Brien, J.F.

  • Author_Institution
    WESTINGHOUSE ELECTRIC CORPORATION Nuclear Energy Systems
  • Issue
    2
  • fYear
    1978
  • fDate
    3/1/1978 12:00:00 AM
  • Firstpage
    358
  • Lastpage
    361
  • Abstract
    The recently approved industry standard ANSI-N6581, "Single Failure Criteria for PWR Fluid Systems", expands the definition of active failure to include the spurious action of a powered component but allows exemption for components whose reliable operation can be demonstrated. This report is a summary of the methodologies employed to demonstrate such reliable operation for certain emergency core cooling system (ECCS) motor operated valves. It is intended that this treatment of a single failure issue will increase the awareness of the industry to the potential role of quantitative analysis in determining failure criteria for nuclear power generating stations.
  • Keywords
    ANSI standards; Circuit faults; Cooling; Electrical equipment industry; Failure analysis; Fires; Maintenance; Power system reliability; Statistical analysis; Valves;