DocumentCode :
837556
Title :
High-frequency current-source inverters using SI thyristors for induction heating applications
Author :
Peng, Fang Zheng ; Akagi, Hirofumi ; Nabae, Akira ; Sugawara, Shogo
Author_Institution :
Fac. of Eng., Technol. Univ. of Nagaoka, Niigata, Japan
Volume :
25
Issue :
1
fYear :
1989
Firstpage :
172
Lastpage :
180
Abstract :
An optimum control scheme for current-source inverters using static induction thyristors in various high-frequency induction heating applications is described. The optimum control scheme implies an optimal control of the firing angle and extinction angle relative to the output voltage in order to minimize the surge voltage and the switching loss during the commutation interval. The tailing current problems of the SI thyristors which significantly influence the optimum firing angle and extinction angle are discussed theoretically. The validity of the optimum control scheme is verified by experiments with a 78 kHz, 17.4 kW (290 V, 60 A) inverter
Keywords :
induction heating; invertors; optimal control; thyristor applications; 17.4 kW; 290 V; 60 A; 78 kHz; commutation; current-source inverters; extinction angle; firing angle; induction heating; optimal control; static induction thyristors; thyristor applications; Anodes; Frequency; Inductance; Inverters; MOSFETs; Optimal control; Surges; Switching loss; Thyristors; Voltage control;
fLanguage :
English
Journal_Title :
Industry Applications, IEEE Transactions on
Publisher :
ieee
ISSN :
0093-9994
Type :
jour
DOI :
10.1109/28.18887
Filename :
18887
Link To Document :
بازگشت