• DocumentCode
    837977
  • Title

    The Production of 123I and 84Rb at the University of Manitoba Cyclotron Laboratory

  • Author

    Gusdal, M.I. ; McKee, J.S.C. ; Billinghurst, M. ; Sutherland, J.B. ; Sharma, G.P.

  • Author_Institution
    Cyclotron Laboratory, Department of Physics, University of Manitoba, Winnipeg, Manitoba, R3T 2N2, Canada
  • Volume
    26
  • Issue
    2
  • fYear
    1979
  • fDate
    4/1/1979 12:00:00 AM
  • Firstpage
    2269
  • Lastpage
    2270
  • Abstract
    Production of 123I from the reaction 124Te(p,2n)123I is proceeding on a routine basis using a target similar to that developed at the A. V. F. cyclotron laboratory in Milan. It is believed that the current output may be sufficient to meet the Canadian need for thyroid scans at this time. The production of 84Rb has also recently been undertaken using the 84Kr(p,n)84Rb reaction on enriched 84Kr. The Rb is being used at St. Boniface General Hospital to trace blood flow patterns through the heart. Additional plans exist for the production of 81mRb from irradiation of natural krypton.
  • Keywords
    Assembly; Blood flow; Cooling; Costs; Cyclotrons; Heart; Hospitals; Laboratories; Production systems; Radioactive materials;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1979.4329854
  • Filename
    4329854