DocumentCode :
838363
Title :
Volumetric ultrasound imaging using 2-D CMUT arrays
Author :
Oralkan, Ömer ; Ergun, A. Sanh ; Cheng, Ching-Hsiang ; Johnson, Jeremy A. ; Karaman, Mustafa ; Lee, Thomas H. ; Khuri-Yakub, Butrus T.
Author_Institution :
Edward L. Ginzton Lab., Stanford Univ., CA, USA
Volume :
50
Issue :
11
fYear :
2003
Firstpage :
1581
Lastpage :
1594
Abstract :
Recently, capacitive micromachined ultrasonic transducers (CMUTs) have emerged as a candidate to overcome the difficulties in the realization of 2-D arrays for real-time 3-D imaging. In this paper, we present the first volumetric images obtained using a 2-D CMUT array. We have fabricated a 128/spl times/128-element 2-D CMUT array with through-wafer via interconnects and a 420-/spl mu/m element pitch. As an experimental prototype, a 32/spl times/64-element portion of the 128/spl times/128-element array was diced and flip-chip bonded onto a glass fanout chip. This chip provides individual leads from a central 16/spl times/16-element portion of the array to surrounding bondpads. An 8/spl times/16-element portion of the array was used in the experiments along with a 128-channel data acquisition system. For imaging phantoms, we used a 2.37-mm diameter steel sphere located 10 mm from the array center and two 12-mm-thick Plexiglas plates located 20 mm and 60 mm from the array. A 4/spl times/4 group of elements in the middle of the 8/spl times/16-element array was used in transmit, and the remaining elements were used to receive the echo signals. The echo signal obtained from the spherical target presented a frequency spectrum centered at 4.37 MHz with a 100% fractional bandwidth, whereas the frequency spectrum for the echo signal from the parallel plate phantom was centered at 3.44 MHz with a 91% fractional bandwidth. The images were reconstructed by using RF beamforming and synthetic phased array approaches and visualized by surface rendering and multiplanar slicing techniques. The image of the spherical target has been used to approximate the point spread function of the system and is compared with theoretical expectations. This study experimentally demonstrates that 2-D CMUT arrays can be fabricated with high yield using silicon IC-fabrication processes, individual electrical connections can be provided using through-wafer vias, and flip-chip bonding can be used to inte- - grate these dense 2-D arrays with electronic circuits for practical 3-D imaging applications.
Keywords :
micromachining; phantoms; ultrasonic imaging; ultrasonic transducer arrays; wafer bonding; 12 mm; 128-channel data acquisition system; 2.37 mm; 20 mm; 3.44 MHz; 4.37 MHz; 60 mm; Plexiglas plates; RF beamforming; capacitive micromachined ultrasonic transducers; dense 2-D arrays; echo signal; electrical connections; electronic circuits; experimental prototype; flip chip bonding; fractional bandwidth; frequency spectrum; glass fanout chip; image reconstruction; imaging phantoms; interconnects; multiplanar slicing techniques; parallel plate phantom; point spread function; practical 3-D imaging applications; real time 3-D imaging; silicon IC-fabrication processes; spherical target; steel sphere; surface rendering; synthetic phased array; volumetric images; volumetric ultrasound imaging; Bandwidth; Bonding; Frequency; Imaging phantoms; Integrated circuit interconnections; Phased arrays; Prototypes; Ultrasonic imaging; Ultrasonic transducer arrays; Ultrasonic transducers; Algorithms; Equipment Failure Analysis; Image Enhancement; Image Interpretation, Computer-Assisted; Imaging, Three-Dimensional; Nucleocapsid Proteins; Phantoms, Imaging; Transducers; Ultrasonography;
fLanguage :
English
Journal_Title :
Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-3010
Type :
jour
DOI :
10.1109/TUFFC.2003.1251142
Filename :
1251142
Link To Document :
بازگشت