• DocumentCode
    838364
  • Title

    Breakdown Mechanism Studies in XLPE Cable -- Part II

  • Author

    McKean, A.L. ; Tsuji, K. ; Doepken, H.C., Jr. ; Zidon, A.

  • Author_Institution
    Phelps Dodge Cable & Wire Company
  • Issue
    4
  • fYear
    1978
  • fDate
    7/1/1978 12:00:00 AM
  • Firstpage
    1167
  • Lastpage
    1176
  • Abstract
    This research explores the basic hypothesis that microporosity plays a significant role in the mechanism of breakdown at high stress(15 to 30 times operating stress). The relative performance of gas-impregnated cable models on volt-time studies at several pressures and with several gases is analyzed using established gas breakdown techniques.
  • Keywords
    Breakdown voltage; Cables; Corona; Dielectric liquids; Dielectrics and electrical insulation; Electric breakdown; Gases; Partial discharges; Stress; Testing;
  • fLanguage
    English
  • Journal_Title
    Power Apparatus and Systems, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9510
  • Type

    jour

  • DOI
    10.1109/TPAS.1978.354597
  • Filename
    4181544