  • Abstract
    Successful electron cooling of antiproton beams requires a precisely aligned and high quality electron beam. Mean e- momentum and energy are to be held within 0.25 mrad and ¿ eV respactively. In addition the e- "temperature" about this mean (rest frame velocity spread) should be held to ¿¿ eV. The diagnostics required to align the beam in angle and energy are rather straightforward. The temperature measuring diagnostics (one for T¿; one for T¿) are more exotic.