DocumentCode
839697
Title
Electron Beam Diagnostics in the Fermilab Electron Cooling Experiment
Author
Kells, W. ; McIntyre, P.M.
Author_Institution
Fermi National Accelerator Laboratory, P. O. Box 500, Batavia, Illinois 60510
Volume
26
Issue
3
fYear
1979
fDate
6/1/1979 12:00:00 AM
Firstpage
3300
Lastpage
3301
Abstract
Successful electron cooling of antiproton beams requires a precisely aligned and high quality electron beam. Mean e- momentum and energy are to be held within 0.25 mrad and ¿ eV respactively. In addition the e- "temperature" about this mean (rest frame velocity spread) should be held to ¿¿ eV. The diagnostics required to align the beam in angle and energy are rather straightforward. The temperature measuring diagnostics (one for T¿; one for T¿) are more exotic.
Keywords
Cooling; Electron beams; Energy measurement; Laser beams; Monitoring; Solenoids; Stability; Structural beams; Temperature measurement; Voltage;
fLanguage
English
Journal_Title
Nuclear Science, IEEE Transactions on
Publisher
ieee
ISSN
0018-9499
Type
jour
DOI
10.1109/TNS.1979.4330015
Filename
4330015
Link To Document