• DocumentCode
    839918
  • Title

    Improvement of a beam position monitor for Δr feedback on RF system

  • Author

    Ishimaru, Hajime ; Kondoh, Motoo ; Shibata, Shinkichi

  • Volume
    26
  • Issue
    3
  • fYear
    1979
  • fDate
    6/1/1979 12:00:00 AM
  • Firstpage
    3361
  • Lastpage
    3363
  • Abstract
    When the beam intensity of the 12 GeV proton synchrotron is increased, oscillations occur in the radial direction of the beam, and the beam loss increases at the phase transition. The beam loss at the transition point was due to the ΔR feedback system oi RF acceleration. The ordinary electrostatic pickup1) used for RF feedback system was replaced with a new large size pickup2). Improvements were made in the following respects: 1. large size to obtain high signal to noise ratio, 2. no side walls to eliminate the noise due to beam hitting, 3. smooth ground for the shield electrode, 4. minimization of the distance between the electrode and vacuum feedthrough and the insertion of an oscillation damping resistor between them, 5. calibration wires were installed between the sensing electrode and the shield electrode. Electrode signals were processed by an average type rectifier and normalizer. The position signal was fed to an RF system through an analogue isolator. This paper deals with the modifications in the beam position feedback of the RF system.
  • Keywords
    Acceleration; Electrodes; Electrostatics; Feedback; Monitoring; Particle beams; Protons; Radio frequency; Signal to noise ratio; Synchrotrons;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1979.4330036
  • Filename
    4330036