DocumentCode :
840158
Title :
Beam Position Monitor Using a Single Cavity
Author :
McKeown, Joseph
Author_Institution :
Atomic Energy of Canada Limited Physics Division, Chalk River Nuclear Laboratories Chalk River, Ontario, Canada KOJ 1JO
Volume :
26
Issue :
3
fYear :
1979
fDate :
6/1/1979 12:00:00 AM
Firstpage :
3423
Lastpage :
3425
Abstract :
Beam tests have been carried out with a cylindrical cavity tuned to 2.415 GHz which is the third harmonic of the accelerator frequency. The beam excites a TM110-like mode when the centroid is displaced horizontally and an orthogonal mode when the beam is displaced vertically. The phase reversal detected when the beam crosses the plane of symmetry identifies the cartesian quadrant occupied by the beam. The signals are proportional to beam current and displacement with average slope 0.35 mW1/2.mm-1. mA-1.