• DocumentCode
    840744
  • Title

    Pulp friction: reconditioning pulp and paper mill generators for reliable service

  • Author

    Moore, William G.

  • Volume
    12
  • Issue
    2
  • fYear
    2006
  • Firstpage
    52
  • Lastpage
    60
  • Abstract
    Generators are very efficient and are typically quite reliable. This article describes, key preventive maintenance actions, along with recommended cycle times of the generator. Initially, the basic preventive maintenance tasks such as visual inspection of generator components, particularly the stator windings, rotors and wedge system is discussed. An extensive generator health assessment should be done to determine what problems are most severe and need priority attention.
  • Keywords
    electric generators; paper mills; preventive maintenance; reliability; rotors; stators; generator health assessment; paper mill generators; preventive maintenance action; pulp friction; pulp reconditioning generators; reliability; rotor; stator winding; visual inspection; wedge system; Coils; Friction; Inspection; Insulation; Partial discharges; Preventive maintenance; Rotors; Stators; Surface treatment; Testing;
  • fLanguage
    English
  • Journal_Title
    Industry Applications Magazine, IEEE
  • Publisher
    ieee
  • ISSN
    1077-2618
  • Type

    jour

  • DOI
    10.1109/MIA.2006.1598027
  • Filename