• DocumentCode
    841298
  • Title

    Acoustic Resonance Avoidance in High Pressure Sodium Lamps Via Third Harmonic Injection in a PWM Inverter-Based Electronic Ballast

  • Author

    Morais, Lenin Martins Ferreira ; Donoso-Garcia, Pedro Francisco ; Seleme, Seleme Isaac, Jr. ; Cortizo, Porfírio Cabaleiro

  • Author_Institution
    Univ. Fed. de Minas Gerais, Belo Horizonte
  • Volume
    22
  • Issue
    3
  • fYear
    2007
  • fDate
    5/1/2007 12:00:00 AM
  • Firstpage
    912
  • Lastpage
    918
  • Abstract
    Third harmonic injection in the high pressure sodium lamp voltage by means of a controlled pulsewidth modulation inverter is studied in this paper. It can be shown that acoustic resonance can be avoided by using this technique with a judicious amount of third harmonic injection. Furthermore, the crest factor in the lamp current can also be reduced
  • Keywords
    PWM invertors; acoustic resonance; lamp accessories; lamps; PWM inverter; acoustic resonance avoidance; crest factor; electronic ballast; high pressure sodium lamps; pulsewidth modulation inverter; third harmonic injection; Acoustic pulses; Electronic ballasts; Fault location; Fluctuations; Frequency; Lamps; Pulse width modulation; Pulse width modulation inverters; Resonance; Switches; Acoustic resonance (AR) avoidance; harmonic injection; high pressure sodium (HPS) lamps; pulsewidth modulation (PWM);
  • fLanguage
    English
  • Journal_Title
    Power Electronics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8993
  • Type

    jour

  • DOI
    10.1109/TPEL.2007.896993
  • Filename
    4182473