DocumentCode :
843572
Title :
X-Ray Fluorescence with Synchrotron Radiation
Author :
Sparks, C.J., Jr. ; Raman, S. ; Ricci, E. ; Krause, M.O. ; Gentry, R.V.
Author_Institution :
Oak Ridge National Laboratory, Oak Ridge, Tennessee 37830
Volume :
26
Issue :
1
fYear :
1979
Firstpage :
1368
Lastpage :
1372
Abstract :
An experimental set-up for x-ray fluorescence analysis with synchrotron radiation was built and installed at the Stanford Synchrotron Radiation Project. X-ray spectra were taken from numerous and varied samples in order to assess the potential of synchrotron radiation as an excitation source for multielement x-ray fluorescence analysis. For many applications, the synchrotron radiation technique is shown to be superi- or to other x-ray fluorescence methods, especially those employing electrons and protons as excitation sources.
Keywords :
Contracts; Electrons; Fluorescence; Laboratories; Protons; Signal to noise ratio; Sparks; Synchrotron radiation; X-ray detection; X-ray detectors;