DocumentCode :
843906
Title :
Evaluation of Nal(Tl) Scintillator as a Fast Neutron Monitor
Author :
Cecil, F.E. ; Killian, K. ; Rymes, M.
Author_Institution :
Department of Physics Colorado School of Mines, Golden, Colorado 80401
Volume :
26
Issue :
1
fYear :
1979
Firstpage :
1487
Lastpage :
1489
Abstract :
The fast neutron induced reaction 1271(n,n´) followed by the absorption of the 57 keV gamma ray of the deexcitation of the 1271 first excited state allows a conventional Nal(Tl) detector to be utilized as a high efficiency, fast neutron detector. The interaction length for the emission of the 57 keV gamma ray produced by the passage of neutrons of energy 2.8 MeV and 14.1 MeV through Nal(Tl) has been measured. A¿ 2.8 MeV, ¿ = 0.0079 ± 0.0009 cm-1; at 14.1 MeV, ¿ = 0.0050 ± .0005 cm-1.
Keywords :
Electromagnetic wave absorption; Energy measurement; Gamma ray detection; Gamma ray detectors; Monitoring; Neutrons; Plastics; Production; Protons; Scattering;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1979.4330419
Filename :
4330419
Link To Document :
بازگشت