DocumentCode :
844392
Title :
The Tuned Pipeline - A Link between Small Accelerators and Nuclear Medical Needs
Author :
Hichwa, R.D. ; Nickles, R.J.
Author_Institution :
University of Wisconsin Madison, Wisconsin 53706
Volume :
26
Issue :
1
fYear :
1979
Firstpage :
1707
Lastpage :
1709
Abstract :
Short-lived radioactive gases are produced in thick high pressure gas targets for ultimate use as medical imaging agents. Small Teflon capillaries have been used to span the 500 m distance between a Van de Graaff accelerator and a nuclear medicine department. Theoretical calculations model the gas flow through these capillaries for the tuned condition of highest specific activity at 1 atmosphere output pressure. These results compare favorably with experimental data and provide the foundation for a pipeline to a new hospital facility 3000 m away.
Keywords :
Biochemistry; Biomedical imaging; Cyclotrons; Gases; Isotopes; Medical diagnostic imaging; Nuclear medicine; Pipelines; Positrons; Tomography;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/TNS.1979.4330467
Filename :
4330467
Link To Document :
بازگشت