DocumentCode :
845094
Title :
Discussion: Time characteristics of fast pulsed flashover in vacuum (with reply by H. Karner)
Author :
Danikas, M.G. ; Karner, H.C.
Volume :
28
Issue :
1
fYear :
1993
Firstpage :
157
Lastpage :
159
Abstract :
For original paper see H.H. Zhong et al., ibid., vol.27, p.496-503 (1992). The discussor raises five points and adds comments concerning insulator shapes and the delivery of excessive discharge energy. H. Karner replies by first noting that he can answer only partly to some of the questions due to the fact that he wanted to investigate the influence of insulators on the speed of the voltage collapse which he had examined for a free vacuum gap. The discussor however, is mainly interested in strength problems of gaps with insulators, which he investigated only to a small extent.<>
Keywords :
flashover; surface discharges; vacuum insulation; discharge energy; fast pulsed flashover; free vacuum gap; insulator shapes; surface charges; time characteristics; voltage collapse speed; Epoxy resins; Flashover; Geometry; Impulse testing; Plastic insulation; Proposals; Shape; Vacuum systems; Voltage;
fLanguage :
English
Journal_Title :
Electrical Insulation, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9367
Type :
jour
DOI :
10.1109/14.192254
Filename :
192254
Link To Document :
بازگشت