A new method for representation of hysteresis loops
Author :
Lin, C.E. ; Wei, J.-B. ; Huang, C.L. ; Huang, C.J.
Author_Institution :
Cheng Kung Univ., Tainan, Taiwan
fDate :
1/1/1989 12:00:00 AM
Abstract :
The i-φ hysteresis characteristic of a transformer is modeled and simulated by a curve-fitting technique, including a consuming function for representing hysteresis loss. The method is established on the basis of measured hysteresis data and allows direct calculation of hysteresis losses. The analytical expression also exhibits the property of increasing the loop area with increment of operating frequency. The simulation results are compared with experiments, and good agreement is shown. The approach can be adapted to determine an accurate transformer hysteresis characteristic by a simplified procedure
Keywords :
hysteresis; power transformers; curve-fitting technique; hysteresis loops; transformer; Circuit faults; Frequency; Magnetic hysteresis; Mathematical model; Power system protection; Power system relaying; Power system simulation; Power system transients; Power transformers; Surge protection;
Journal_Title :
Power Delivery, IEEE Transactions on