DocumentCode
845685
Title
A new concept for a three-terminal admittance bridge with self-calibration capability
Author
Grno, Ladislav
Author_Institution
Czechoslovak Inst. of Metrol., Bratislava, Czechoslovakia
Volume
38
Issue
2
fYear
1989
fDate
4/1/1989 12:00:00 AM
Firstpage
381
Lastpage
383
Abstract
An approach to a three-terminal admittance measurement utilizing a novel concept of a bridge circuit with self-calibration capability is described. The coaxial design of the network is compatible with the two-terminal pair definition of impedance standards and enables the realization of a simple bridge circuit with a noniterative calibration procedure
Keywords
bridge circuits; bridge instruments; calibration; coaxial cables; electric admittance measurement; measurement standards; bridge circuit; coaxial design; electric admittance measurement; impedance standards; noniterative calibration; self-calibration; three-terminal admittance bridge; two-terminal pair definition; Admittance measurement; Bridge circuits; Calibration; Circuit stability; Coaxial cables; Coaxial components; Detectors; Impedance; Joining processes; Time measurement;
fLanguage
English
Journal_Title
Instrumentation and Measurement, IEEE Transactions on
Publisher
ieee
ISSN
0018-9456
Type
jour
DOI
10.1109/19.192311
Filename
192311
Link To Document