DocumentCode :
845712
Title :
An international comparison of power meter calibrations conducted in 1987
Author :
Moore, William J M ; So, Eddy ; Oldham, Nile M. ; Miljanic, Etar N. ; Bergeest, Rainer
Author_Institution :
Nat. Res. Council of Canada, Ottawa, Ont., Canada
Volume :
38
Issue :
2
fYear :
1989
fDate :
4/1/1989 12:00:00 AM
Firstpage :
395
Lastpage :
401
Abstract :
The results of an intercomparison of power meter calibrations conducted during 1987 between the National Research Council of Canada, Ottawa, the US National Bureau of Standards, Gaithersburg, the Physikalisch-Technische Bundesanstalt, Braunschweig, and the Institut Mihailo Pupin, Belgrade, are described. The comparison was implemented by a transfer standard consisting of a time-division multiplier watt-converter developed at the Institut Mihailo Pupin. The measurements were made at 120 V, 5 A, and 50 and 60 Hz, at power factors of 1.0, 0.5 lead and lag, and 0.0 lead and lag. An agreement between the laboratories of better than 20 ppm is obtained
Keywords :
calibration; power measurement; 120 V; 1987; 5 A; 50 Hz; 60 Hz; Institut Mihailo Pupin; National Research Council of Canada; Physikalisch-Technische Bundesanstalt; US National Bureau of Standards; international comparison; power meter calibrations; time-division multiplier watt-converter; transfer standard; Calibration; Councils; Instruments; Laboratories; NIST; Power measurement; Reactive power; Standards development; Switches; Voltage;
fLanguage :
English
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9456
Type :
jour
DOI :
10.1109/19.192314
Filename :
192314
Link To Document :
بازگشت