DocumentCode :
846685
Title :
Measurements and Correction of the PEP Interaction Region Quadrupole Magnets
Author :
Main, R.M. ; Tanabe, J.T. ; Halbach, K.
Author_Institution :
Lawrence Berkeley Laboratory
Volume :
26
Issue :
3
fYear :
1979
fDate :
6/1/1979 12:00:00 AM
Firstpage :
4030
Lastpage :
4032
Abstract :
Lenses for the intersection regions of PEP must be pure quadrupole over the entire magnet aperture to within 1:104. Correction of the magnet and its end fringe regions to this accuracy requires measurement of the field quality (relative field harmonic component amplitudes at the pole radius) to 1:105 through the 30th harmonic. Equipment developed for these measurements and the techniques used for field correction are described.