Title :
Measurements and Correction of the PEP Interaction Region Quadrupole Magnets
Author :
Main, R.M. ; Tanabe, J.T. ; Halbach, K.
Author_Institution :
Lawrence Berkeley Laboratory
fDate :
6/1/1979 12:00:00 AM
Abstract :
Lenses for the intersection regions of PEP must be pure quadrupole over the entire magnet aperture to within 1:104. Correction of the magnet and its end fringe regions to this accuracy requires measurement of the field quality (relative field harmonic component amplitudes at the pole radius) to 1:105 through the 30th harmonic. Equipment developed for these measurements and the techniques used for field correction are described.
Keywords :
Assembly; Coils; Computer errors; Counting circuits; Error correction; Laboratories; Magnetic field measurement; Magnets; Stacking; Vibration measurement;
Journal_Title :
Nuclear Science, IEEE Transactions on
DOI :
10.1109/TNS.1979.4330687