• DocumentCode
    846903
  • Title

    The Doublet III Neutral Beam Source Cryopanel System

  • Author

    Tanabe, Jack ; Yamamoto, Robert ; Arend, Peter Vander

  • Volume
    26
  • Issue
    3
  • fYear
    1979
  • fDate
    6/1/1979 12:00:00 AM
  • Firstpage
    4080
  • Lastpage
    4082
  • Abstract
    A cryogenic pumping system is designed to provide 1.4 × 106 l/sec. of hydrogen pumping speed for the Doublet III neutral beam ion source. The cryopump is made up of two elements; a cylindrical unit which uses a "Santeler" type of liquid nitrogen shield and a flat chevron shielded disk. Liquid helium and liquid nitrogen are circulated by forced flow. The liquid helium is circulated at 0.6 atm absolute pressure for cryopump operation at 3.8°K.
  • Keywords
    Circuits; Cryogenics; Fluid flow; Helium; Hydrogen; Laser excitation; Nitrogen; Pumps; Structural beams; Tokamaks;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.1979.4330705
  • Filename
    4330705