• DocumentCode
    84756
  • Title

    Preoperative Ambulatory Measurement of Asymmetric Leg Loading During Sit-to-Stand in Hip Arthroplasty Patients

  • Author

    Martinez-Ramirez, Alicia ; Weenk, Dirk ; Lecumberri, Pablo ; Verdonschot, Nico ; Pakvis, Dean ; Veltink, Peter H.

  • Author_Institution
    Math. Dept., Public Univ. of Navarra, Pamplona, Spain
  • Volume
    22
  • Issue
    3
  • fYear
    2014
  • fDate
    May-14
  • Firstpage
    585
  • Lastpage
    592
  • Abstract
    Total hip arthroplasty (TGA) is a successful surgical procedure to treat patients with hip osteoarthritis. Clinicians use different questionnaires to evaluate these patients. Gait velocity and these questionnaires; usually show significant improvement after TGA . This clinical evaluation does, however, not provide objective, quantifiable information about the movement patterns underlying the functional capacity, which is clinically important and can currently only be obtained in a gait laboratory. There is a need to improve patient instructions and to quantify the rehabilitation process. The sit-to-stand (STS) movement is an objective performance-based task, whose assessment is related with the evaluation of functional recovery. Twenty two patients with hip osteoarthritis participated in this study. For each patient, validated questionnaires were administered and gait velocity was measured. Time, ground reaction forces, and lower limb asymmetry parameters were calculated using the instrumented force shoes (IFS) during STS movement with and without armrest. Significant inter-limb asymmetry was observed. No correlation was found between any parameter and gait velocity and questionnaires outcomes. Significant differences in time and force parameters between with/without armrest were found. Concluding, inter-limb asymmetry can be evaluated with the IFS supplying important additional information not represented by gait velocity and questionnaires usually used.
  • Keywords
    biomedical measurement; diseases; footwear; force measurement; gait analysis; orthopaedics; patient rehabilitation; surgery; armrest; asymmetric leg loading; clinical evaluation; functional capacity; functional recovery evaluation; gait laboratory; gait velocity; ground reaction forces; hip arthroplasty patients; instrumented force shoes; interlimb asymmetry; lower limb asymmetry parameters; movement patterns; objective performance-based task; patient instructions; patient treatment; preoperative ambulatory measurement; questionnaires; rehabilitation process; sit-to-stand movement; surgical procedure; Gait parameters; ground reaction forces; instrumented force shoes (IFS); inter-limb asymmetry; sit-to-stand (STS); total hip replacement;
  • fLanguage
    English
  • Journal_Title
    Neural Systems and Rehabilitation Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1534-4320
  • Type

    jour

  • DOI
    10.1109/TNSRE.2013.2263394
  • Filename
    6522523