DocumentCode :
847846
Title :
Influence of the delay of the first corona pulse on the switching impulse breakdown probability
Author :
Menemenlis, C. ; Anis, H.
Author_Institution :
Hydro-Quebec Institute of Research, Varennes, Quebec, Canada
Volume :
94
Issue :
2
fYear :
1975
fDate :
3/1/1975 12:00:00 AM
Firstpage :
455
Lastpage :
466
Abstract :
Tests with a rod-plane gap with a rounded termination of the rod show that the delay of the first corona pulse affects the positive switching impulse breakdown probability. The inverted S form or local inconsistencies of the breakdown probability distribution are connected with particular statistical features of the delay of the first corona pulse. The influence of the rod termination or the impulse front on the breakdown probability distribution is explained in terms of the delay of the first corona pulse.
Keywords :
Breakdown voltage; Corona; Delay; Electric breakdown; Electrodes; IEEE members; Impulse testing; Insulation; Probability distribution; Pulse shaping methods;
fLanguage :
English
Journal_Title :
Power Apparatus and Systems, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9510
Type :
jour
DOI :
10.1109/T-PAS.1975.31872
Filename :
1601474
Link To Document :
بازگشت